Role of Percutaneous Transluminal Angioplasty in failing stenotic hemodialysis AV fistula.
Abstract
PURPOSE:To evaluate the role of interventional radiology in salvaging hemodialysis access sites in patients of end stage renal disease with a specific attention to features that may predict a poor outcome.
METHODS: A total of 26 patients with dysfunctional hemodialysis AVF’s were taken up for PTA with or without stent placement. All patients underwent a pre and post procedural USG Doppler to assess parameters like mean flow, mean PSV and vessel diameter. Technical and clinical success rates were calculated and characteristics causing increased failure rates (long segment and multi site stenosis and diabetes) were noted
RESULTS:Majority (34.6%) of patients had venous distal segment stenosis, 30.8% had Anastomotic stenosis, 23.1% had venous peri[1]anastomotic stenosis and 11.5% of patients had central venous stenosis & most of patients had only one stenotic short segment lesion. 100% patients in our study population had technical success on percutaneous transluminal angioplasty and among them 80.8% maintained patency of fistula at three months of follow up, however this rate decreased to 69.2% at 6 months of follow up (both were statistically significant). Common characteristics in patients with failure (primary or secondary) were diabetes, increased age and most importantly increased length of stenosis (> 2cm) and multi site stenosis. USG Doppler parameters showed a significant improvement post PTA (p <0.001) indicating clinical success. No major complication was noted in our study.
CONCLUSION: PTA is the answer to dysfunctional hemodialysis access. Careful selection of patients can improve the success rates and decrease the economic burden in a resource constrained country like ours. USG Doppler is an essential component in the assessment of iatrogenic hemodialysis AVF’s.
Downloads